Buzz World 365 Logo

Heizung wird nur oben warm - Heizkörper wird nur zur Hälfte warm - Das ist der Grund und die Lösu

Nov 12, 2022

Heizung wird nur oben warm - Heizkörper wird nur zur Hälfte warm - Das ist der Grund und die Lösu

hello and welcome to a new video good thing you turned it on again in your apartment in the house or in the room it's quite cold even though the heating is on it's just not going to work well the heating was already ordered here for 5 essays It's pretty hot too, but the deeper we go the colder the heating, it's only half as bad really, what can you do? I would like to explain that to you here in the video and above all tell you that the problem could be solved on its own without expensive ones, but considering that it makes little sense in the first place, that means setting the thermostat to level 5, which it would be a maximum room temperature of 8 to 20 degrees which is of course too

warm

and above all much, much too much. expensive turns rather the heating is on level 3 there is a room temperature between 20 and 22 degrees depending on how the heating works how the house is set up etc how big it is but that is actually a normal indoor temperature one can recommend and how one can still pay at the end before telling them now why I keep working on our half.
heizung wird nur oben warm   heizk rper wird nur zur h lfte warm   das ist der grund und die l su
I have a small concern on my own behalf. Fortunately I am very successful many viewers have a youtube video which makes me very happy unfortunately only two to three percent of viewers have also subscribed to a youtube channel which I think is a shame , if i can help with the video here or if you like it then i would be very happy if you are also on but here on youtube almost everything is free for you it helps me a lot here as well as thumbs up by the way if you really liked it the video here or it was useful let's start and I will not say what is the reason that I really did not want to support the heating, but only half of what was now exactly the reason that the heating only year the top heats up and the bottom stays cold in nine out of ten cases it's not really a fault in the heating we don't have to worry about expensive bills from dealers it's usually always the case that there is actually air in the system issue and of course it has to come out that means the heater has to be bled I'll show you how to do it again in a moment but there can always be another case that can happen that the valve of the heater valve is stuck and the solid part Yes. it doesn't open properly, even then the radiator won't work properly.
heizung wird nur oben warm   heizk rper wird nur zur h lfte warm   das ist der grund und die l su
I'll link you to a video here that you could fix it yourself. It is also relatively easy and fast. You do not need to hire a specialized company. You can really do it yourself. You can save money and above all you will have a

warm

used apartment immediately because you do not just wait for a craftsman, but in most cases now it is with the cold from the heating element below. For the heat you only heat on top, the reason is with air and how we counteract it. level 5 now it is important if you have the opportunity and heating is also accessible for you in some rented apartments it is very difficult but if you have the opportunity turn off the circulation pump on heating or the circulation pump could be turned off directly for you if that not possible if you So now you don't have a mains socket or the circulation pump is also not so obvious to you then just turn off the heating completely, in my case I have an app for this which means I can turn off my system of heating through the app, if you don't have it, you should probably turn it on to check the operation of your heating because of course you can also turn the heating off there now we have turned all the radiators on to level five, after that we turn the heating off central once, now we must wait ten minutes because it only accumulates in the radiator and that is why it is also important turn off the circulation pump, because otherwise the air will keep coming back, it would usually be implemented for air to collect where the soft core of the years is your boiler heater radiator, usually if you have several days, for example, of course, the upper floor that means the other way around, you have to start with the ventilation through the radiator closest to your boiler, from there you always progress to the furthest one and in the end we have to stop with the ventilation through the farthest and tallest radiator which is is best needed once a container in cee still takes it to have a cloth ready and then needs such ventilation the key unlocks that problem i would always miss because you don't mess with pliers or something that I don't do for other possibilities even if you have a slot for a stepped screwdriver that should only be an emergency fix because it often frays or makes it round and at some point you can't anymore open it and then it breaks then you have to change it first the rear light has I can link you to my video description below it costs euros then it finally fits I don't know exactly otherwise there are also very cheap in hardware stores to buy now let's start with the bleeding i'll show you here with this radiator how to bleed it works the same for all other radiators important again that here of course the neck won first take the closest one as well the distance is the shortest to your boiler at first and then it gets further and further away from the distance so that at the end then the last thing to do is air out the radiator that is furthest from your boiler take the cloth i always pack it on the floor to protect the floor area a bit then i take my key here it could well be that now for the example a radiator where you start there is also no air in it the air takes you further or gives up that means the radiator is there the last fan will probably have the most air too I think you won't get much air out of here now and set the faucet right then turn it on and then yeah one gets to me now after a bit of air water comes out now and if only water comes out , so advise it again we don't have to somehow run out of several hundred milliliters or the whole glass has to be full if there really is no more air then turn it back because it's so tight it's tight but it's not it's so tight we won't be able to reopen it in the future now we're moving on to the next radiator I'm not going to show you I'm getting further and further away from the distances and I'm going to air out the name then tell you how now it continues straight away after I've bled all the radiators let's turn the heating back on.
heizung wird nur oben warm   heizk rper wird nur zur h lfte warm   das ist der grund und die l su
I do this in this case in my application either stop directly at the heating or separate the circulation. pump again so I can show you everything now unfortunately I don't have all the radiators at home but I have my heater so I briefly showed you how a heater works. The next thing to do is check the water pressure in your radiator. It is better to also look at the operating instructions to see what water pressure should be there if the water pressure is too low, please fill with water if necessary. I will show you how to do this in a video that I link to you here.
heizung wird nur oben warm   heizk rper wird nur zur h lfte warm   das ist der grund und die l su
It seems good to me, I also have modern heating that now regulates it automatically by itself. Now of course, a very important point is to lower the heating thermostats in your house a little. I will do it Don't forget a drop in level 3 somewhere in level five. The worst part of the meat is still in the hallway, where you hardly ever mean anything or only very little, which can be expensive, so reset your heating thermostats again, and then of course check the heating there even now. it was the case with me, by the way, it is also the case that the heating is of course always a little

warm

er than below that there is a certain deviation here it is quite normal that the heat rises upwards then it is ok anyway, for of course the radiator should be on the bottom not be completely cold or very cold the gradient between

warm

and cold top and bottom should not be too great if that is the case you have just seen what you can do by venting the radiators or just the alternative where i linked the video here with the hot quoted at the beginning once on these are really the most common causes why the heating was only up but stays cold downstairs i hope it failed again and most of all helped more, if so something there and done like i said on a youtube channel and then see you in the next video get up again
heizung wird nur oben warm   heizk rper wird nur zur h lfte warm   das ist der grund und die l su
Trending